RBS6601的TRX1A24,MCTR1B1是什么告警来的?基站端和后台要怎么处理?

问题已开启 普通问题 提问者:jaikyviolet|提问时间:2014-11-30

如题

我要回答

请先 登录 或 注册 再回答问题

问题答案 (1)

 

The temperature of the RUG/RUS/RRUS is in the non-destruction range. The fault ceases when the temperature comes back within the exceptional-operation range.

In the non-destruction range the RUS/RRUS takes autonomous actions to protect itself from being damaged. No function is guaranteed. When the fault ceases the system restart the RUS to ensure functionality.

In the exceptional operation range the RUS has full functionality and degraded performance.

The likely causes of this fault are as follows:

If the fault is issued together with a fan fault, then the most likely cause of the fault is a faulty fan unit.

If the alarm is raised on only one RUG/RUS/RRUS, then it is likely that the unit has developed a fault, in which case it is likely that another fault also has been issued for that unit.

If several units from different subracks have issued the fault, then the most likely cause is a fault at the site, in the RBS air-conditioning or in the cooling system.

 

 解决办法:

Test the climate system.

Reset the RUG/RUS/RRUS.

Use the OMT function Check IDB to identify hardware/IDB inconsistencies

Replace the RUG/RUS/RRUS.

 

 


回答者:decwcx 回答时间:2014-11-30 22:14

最新紧急招聘通信职位

重庆中邮信科集团股份有限公司 聘:云南日常网络优化工程师
需求人数:6 人 地点:昭通市
成都旗讯通信技术有限公司 聘:【四川】招外场测试、后台语音优化
需求人数:7 人 地点:成都市,攀枝花市,南充市,内江市,资阳市
珠海世纪鼎利科技股份有限公司 聘:浙江45G室分测试人员 (外场)
需求人数:5 人 地点:温州市,台州市,衢州市,丽水市,金华市
广东南方通信建设有限公司 聘:佛山联通集中优化-高铁专项
需求人数:1 人 地点:佛山市
南京华苏科技有限公司 聘:4/5G系统分析高级高级工程师
需求人数:4 人 地点:郑州市
上海德专信息技术有限公司 聘:内蒙联通网优初级
需求人数:6 人 地点:内蒙古
嘉环科技股份有限公司 聘:网优高级工程师
需求人数:2 人 地点:长沙市
杭州东信网络技术有限公司 聘:福建移动日常项目后台
需求人数:3 人 地点:厦门市,龙岩市,漳州市
深圳市讯方技术股份有限公司 聘:华为45G高级网优工程师
需求人数:5 人 地点:济南市

热点问题

联系我们 - 问通信专家 Powered by MSCBSC 移动通信网  © 2006 -