RBS6601的TRX1A24,MCTR1B1是什么告警来的?基站端和后台要怎么处理?

问题已开启 普通问题 提问者:jaikyviolet|提问时间:2014-11-30

如题

我要回答

请先 登录 或 注册 再回答问题

问题答案 (1)

 

The temperature of the RUG/RUS/RRUS is in the non-destruction range. The fault ceases when the temperature comes back within the exceptional-operation range.

In the non-destruction range the RUS/RRUS takes autonomous actions to protect itself from being damaged. No function is guaranteed. When the fault ceases the system restart the RUS to ensure functionality.

In the exceptional operation range the RUS has full functionality and degraded performance.

The likely causes of this fault are as follows:

If the fault is issued together with a fan fault, then the most likely cause of the fault is a faulty fan unit.

If the alarm is raised on only one RUG/RUS/RRUS, then it is likely that the unit has developed a fault, in which case it is likely that another fault also has been issued for that unit.

If several units from different subracks have issued the fault, then the most likely cause is a fault at the site, in the RBS air-conditioning or in the cooling system.

 

 解决办法:

Test the climate system.

Reset the RUG/RUS/RRUS.

Use the OMT function Check IDB to identify hardware/IDB inconsistencies

Replace the RUG/RUS/RRUS.

 

 

cvmmvK:JFD本文来自移动通信网www.mscbsc.com,版权所有
回答者:decwcx 回答时间:2014-11-30 22:14

最新紧急招聘通信职位

成都旗讯通信技术有限公司 聘:重庆/西安/渭南招室分测试优化
需求人数:9 人 地点:重庆市,西安市,渭南市,宝鸡市,咸阳市
浙江明讯网络技术有限公司 聘:无线网络优化工程师(后台)(湖南)
需求人数:2 人 地点:长沙市,湘潭市
杭州华星创业通信技术股份有限公司 聘:华为后台中高级督导
需求人数:2 人 地点:福州市
嘉环科技股份有限公司 聘:网优高级工程师
需求人数:2 人 地点:长沙市
南京华苏科技有限公司 聘:4/5G系统分析高级高级工程师
需求人数:4 人 地点:郑州市
杭州东信网络技术有限公司 聘:云南华为项目中级工程师
需求人数:1 人 地点:迪庆藏族自治州
珠海世纪鼎利科技股份有限公司 聘:浙江45G室分测试人员 (外场)
需求人数:5 人 地点:温州市,台州市,衢州市,丽水市,金华市

热点问题

联系我们 - 问通信专家 Powered by MSCBSC 移动通信网  © 2006 -