爱立信6601TRX1A24/MCTR1B1
我要回答
问题答案
原因:
TRXC I1A:24 - High Temperature
Description:The temperature of the RUG/RUS/RRUS/AIR is in the non-destruction range. The fault ceases when the temperature is back within the exceptional-operation range.
MCTR I1B:1 - Temperature Exceptional
Description The temperature of the RUS/RRUS is below or above normal conditional range. The fault ceases when the temperature is back within the normal conditional range.
处理:
多个使用RRUS 12的基站在激活后出现以上两个告警,取log发现是使用B1307R066H软件或G10B CPA3网元,是软件或者网元不支持导致的,更改数据后正常。
回答者:OscarDon 回答时间:2018-03-13 17:49