爱立信6000设备TF1A:0是什么告警
如题?
我要回答
问题答案
AO TF I1A:0 - Temperature Below Operational Limit
Description An alarm is raised if the OVCXO temperature falls below
the operational temperature.
The oscillator frequency depends on temperature. Too
low an OVCXO temperature causes timing function
disturbances.
Action Follow the instructions below until the fault is resolved.
• Check for other temperature-related alarms from
this RBS.
• Check if the problem is caused by low ambient
temperature.
• Resolve any RBS external temperature problems.
• Check if the problem is caused by a fault in the RBS
climate system.
• Resolve any RBS climate system problems.
• Replace any faulty RBS external equipment.