爱立信设备 6201 出现 CF 2A 38告警,怎么处理,第一次碰到,请专家帮助,谢谢!
我要回答
问题答案
SO CF I2A:38 - Default Values Used
Description :The DUG is using default parameters for its internal configuration, usually as a consequence of the related faults. Performance can be reduced.
Action: Follow the instructions below until the fault is resolved.
• Reset the DUG.
• Create a new IDB and install it, using the OMT.
Description :The DUG is using default parameters for its internal configuration, usually as a consequence of the related faults. Performance can be reduced.
Action: Follow the instructions below until the fault is resolved.
• Reset the DUG.
• Create a new IDB and install it, using the OMT.
回答者:famine79 回答时间:2013-04-02 23:24
CFI2A38 使用了默认值。由于内部配置的原因,DUG的软件子系统使用了默认参数来配置,其性能会降低。
处理方法: 断电重启DUG;
重新刷卡或格式化CF卡;
用OMT创建新的IDB并安装;
多次安装IDB,问题可能解决。
处理方法: 断电重启DUG;
重新刷卡或格式化CF卡;
用OMT创建新的IDB并安装;
多次安装IDB,问题可能解决。
回答者:w6706 回答时间:2013-04-03 09:35