爱立信RBS2111
TRXC2A:43告警 更换RRU好像解决不了 隔两天又出现求高手帮忙谢谢
我要回答
问题答案
告警解释
SOTRXCI2A:43 -Internal HC Load Power Fault
RelatedFaults
Page72
RelatedRUs
SOTRXCRU:0-TRU,dTRU,DRU,RUG,RRUor
DUG20Page59
Description
The input switch circuitry to the internal hybrid combiner
inthe transceiver unit is broken.
Action
ReplacetheRRU.
SOTRXCI2A:43 -Internal HC Load Power Fault
RelatedFaults
Page72
RelatedRUs
SOTRXCRU:0-TRU,dTRU,DRU,RUG,RRUor
DUG20Page59
Description
The input switch circuitry to the internal hybrid combiner
inthe transceiver unit is broken.
Action
ReplacetheRRU.
回答者:米兰蚂蚁 回答时间:2011-08-16 13:54
SO TRXC I2A:43 - Internal HC Load Power Fault
Related Faults Section 5.10.2 AO TX I1A:1 - Internal HC Load Power
Fault on page 116
Related RUs SO TRXC RU:0 - TRU, dTRU, DRU, RUG, RRU or
DUG 20 Section 4.6 SO TRXC Replacement Unit Map
on page 93
Description The input switch circuitry to the internal hybrid combiner
in the transceiver unit is broken.
Action Replace the DRU.
Related Faults Section 5.10.2 AO TX I1A:1 - Internal HC Load Power
Fault on page 116
Related RUs SO TRXC RU:0 - TRU, dTRU, DRU, RUG, RRU or
DUG 20 Section 4.6 SO TRXC Replacement Unit Map
on page 93
Description The input switch circuitry to the internal hybrid combiner
in the transceiver unit is broken.
Action Replace the DRU.
回答者:520673 回答时间:2011-08-23 01:19