关于爱立信2000的故障代码问题
近段时间我们这里的很多爱立信设备都出了一些2A50以上的故障代码,有人知道是什么故障吗
我要回答
问题答案
|
不知道你能用的上不? SO CF I |
|
CXU supervision/communication lost(CXU监测/通信丢失) |
|
SO CF RU:54 - IOM bus |
|
AO RX I |
|
The DXU has lost communication with the CXU.(这个故障是DXU与CXU通信丢失造成的) |
|
Follow the instructions below until the fault is corrected: |
|
Check at the IDM that the circuit breaker for the CXU is in position ON.(检查IDM空开是否开启) |
|
Check that the CXU DC supply cable is properly connected.(检查CXU DC电缆线是否正确连接) |
|
Check that the required CXUs in the IDB correspond to the CXUs present in the RBS. Otherwise modify the IDB configuration or the RBS hardware.(检查IDB数据中是否配置了CXU) |
|
Check that the IOM bus cable is properly connected to the CXU.(检查IOM总线是否正常连接到CXU) |
|
Power off and on the CXU.(将CXU电源关闭后再开启) |
|
Reset the DXU(重启DXU) |
|
Replace the CXU.(更换CXU) |
|
SO CF I |
|
RX path imbalance(接收通路不平衡) |
|
AO RX I |
|
AO RX I |
|
AO RX I |
|
AO RX I |
|
AO TX I1B:35 - RX path imbalance |
|
SO CF RU:40 - Antenna |
|
This fault occurs together with a pinpointed antenna, if the difference in signal strength between two antennas in the same antenna system exceeds the limits defined using the OMT function Define RX Path Imbalance Parameters. If the class 1 limit is exceeded, the related fault AO TX I1B:35 is also raised and the TX will be disabled.(这个故障的产生是在一个天线系统中两个天线的信号强度差异超出OMT中规定的门限,注意一个天线系统是指OMT上软件定义的Antenna system,两个天线的概念注意是否双极化天线) The supervision of this fault is based on measurements over a long time duration, hence the fault does not cease as soon as the fault condition is corrected. The RX imbalance monitor must therefore be used to verify the correction of the fault condition.(要处理这个故障必须解决故障产生的条件,因为它是持续进行监测的) When the fault condition has been corrected, reset the TRU to cause the fault to terminate immediately.(当处理掉产生故障的条件后,重启TRU故障立即消失) Observe, If the fault condition was not corrected, the fault will be reported again when at least the minimum number of samples has been collected. The minimum number of samples is defined by the Define RX Path Imbalance Parameters function in the OMT.(如果故障产生的条件没有处理好,那么在收集到信号样本后会重新出现) |
|
Follow the instructions below until the fault is corrected: |
|
Check the defined RX path invariance limits using the Define RX Path Imbalance Parameters function in the OMT for the faulty antenna system.(检查OMT中Antenna Supervision Parameters的门限设置) |
|
Check the TX cables/feeders, cable connections inside and outside the cabinet and antennas, for example with Antenna System SWR tests. For information about how to perform a SWR test see Verifying Antenna Systems or Antenna System Tests in the CPI for the relevant RBS.(检查天馈系统,可以做驻波测试来核实) |
|
Reset the TRU(重启TRU) |
| 故障编号------------------------ SO CF I2A:50 |
| 故障名称 RBS 在电池上运行 |
| 具体描述 出现“RBS 目前使用电池运行”的信息。 |
| 操作 根据以下说明排除故障: |
| 􀁺 检查外部电源供给。 |
| 􀁺 检查PSU。 |
| 故障编号------------------------ SO CF I2A:51 |
| 故障名称 TMA无法进行监管/通信 |
| 相关故障 |
| 具体描述 |
| 操作 |
| 故障编号------------------------ SO CF I2A:52 |
| 故障名称 CXU无法进行监管/通信 |
| 31 |
| 相关故障 |
| 具体描述 |
| 操作 |
| 表4 SO CF I2A |
| 故障编号------------------------ SO CF I2A:53 |
| 故障名称 硬件和IDB 不兼容 |
| 具体描述 DXU软件内部配置失败。DXU 不能进行正常操作。 |
| 可能原因 硬件和IDB 不相容,DXU 数据库遭到破坏,Y 链路或EPC 总线出现通信问题。 |
回答者:三江 回答时间:2010-04-22 10:56