ÎÊÌâÒÑ¿ªÆô
(ÆÕͨÎÊÌâ)
S60v3ϵͳÏÂfieldtestÏêϸ²Ù×÷˵Ã÷
ÍøÉÏËѵÄ˵Ã÷¶¼ºÜÁýͳ£¬ÏëÕÒµ½±È½ÏÏêϸµãµÄ¡£
ÌáÎÊÕß: ssswm1979 ÌáÎÊʱ¼ä: 2009-06-04
• temsÀïÃæµÄTXpowerºÍfieLDTEstÓÐɶÇø±ðÓÐɶ¹ØϵÂð 2014-01-20
• android4.0.4 ÊÖ»ú°²×°FieLDTEstÌáʾÊÖ»úÖÐûÓиÃÓ¦ÓÃËùÐèµÄ¹²ÏíÓû§»òÇ©Ãû²»Æ¥Åä.Ôõô½â¾öѽ! 2013-10-16
• ÇëÎÊÒ»ÏÂAndroid 4.04Ôõô°²×°²»ÁËFieLDTEst 2013-10-12
• ŵ»ùÑÇS40¿ÉÓõÄFIELDTEst 2013-03-21
• fieLDTEst²âÊÔWCDMAÐźÅÔõô¿´ÈÅÂë 2012-11-26
• °²×¿ÊÖ»úÓÐfieLDTEstÂ𣿠2012-11-04
• ÏÖÔÚµÄŵ»ùÑÇÊÖ»úÔõô°²×°FIELDTEst²âÊÔÈí¼þ£¿ 2012-09-24
• ÊÖ»úÊÇSONY MT25i£¬ÏëÓÃFieLDTEst£¬ÏëÎʸ÷λ¿ÉÒÔÓò»£¿ 2012-09-19
• android4.0.4 ÊÖ»ú°²×°FieLDTEstÌáʾÊÖ»úÖÐûÓиÃÓ¦ÓÃËùÐèµÄ¹²ÏíÓû§»òÇ©Ãû²»Æ¥Åä.Ôõô½â¾öѽ! 2013-10-16
• ÇëÎÊÒ»ÏÂAndroid 4.04Ôõô°²×°²»ÁËFieLDTEst 2013-10-12
• ŵ»ùÑÇS40¿ÉÓõÄFIELDTEst 2013-03-21
• fieLDTEst²âÊÔWCDMAÐźÅÔõô¿´ÈÅÂë 2012-11-26
• °²×¿ÊÖ»úÓÐfieLDTEstÂ𣿠2012-11-04
• ÏÖÔÚµÄŵ»ùÑÇÊÖ»úÔõô°²×°FIELDTEst²âÊÔÈí¼þ£¿ 2012-09-24
• ÊÖ»úÊÇSONY MT25i£¬ÏëÓÃFieLDTEst£¬ÏëÎʸ÷λ¿ÉÒÔÓò»£¿ 2012-09-19
ÎÊÌâ´ð°¸
( 1 )
´ð:°²×°ºóÖØÆôÊÖ»ú£¬¿ª»úºó»á·¢ÏÖÒѾ³öÏÖÁËFieldTestµÄ³ÌÐò£¨ÔÚN73ÉÏͼ±êÊÇ¿Õ°×£©
3.Èç¹ûÊÇ°²×°°æ°²×°ºó¾Í¿ÉÒÔÖ±½ÓʹÓ㬲»ÐèÒªÖØÆôÊÖ»ú¡£
4.´ò¿ª³ÌÐòºó¿ÉÒÔ¿´µ½ÈçϽçÃ棬ͼƬÖеġ±Chanel num¡±´ú±íµ±Ç°ËùʹÓõĻùÕ¾´úÂ룬ºìȦËùʾµÄµØ·½Ö¸Ê¾µ±Ç°½çÃ棬Èç¹ûÄãҪѰÕÒ»ùÕ¾²¢Ëø¶¨µÄ»°£¬¿ÉÒÔ¼ÌÐø¿´ÏÂÈ¥£¬Èç¹ûÏëÏà¶ÔÏêϸµÄÁ˽⣬¿ÉÒԲο¼ÉÏÃæÌṩµØÖ·ÖеÄÎĵµ¡¶¹¤³ÌģʽÈí¼þʹÓÃС½â¡·¡£
5.°´Ï·½Ïò¼ü¿ÉÒÔÕýÏòÇл»½çÃæ(ÉÏ·½Ïò¼üÄæÏòÇл»½çÃæ)£¬Çл»µ½µ±Çл»½çÃæΪCommon FID 01.03¡¢Common FID 01.04¡¢Common FID 01.05µÄʱºò£¬¾Í¿ÉÒÔ¿´µ½¿ÉÓõĻùÕ¾´úÂë(ÈçÏÂͼºìȦλÖÃ)¡£
6.ÏòÏÂÇл»µ½Common FID 01.12½çÃ棬ÕâÊÇÑ¡ÏîÖлá¶à³öÒ»¸öÑ¡ÏExecute¡±,ÊäÈëÉÏÃæ¿´µ½µÄ»ùÕ¾´úÂëijһ¸ö¼´¿ÉËø¶¨»ùÕ¾£¬Ëø¶¨ºó²âÊÔÐźźÍÏÂÔØËٶȣ¬×îºóËø¶¨Ð§¹û×îºÃµÄ¡£
7.Ëø¶¨»ùÕ¾ºó£¬Èç¹ûÄãÀë»ùÕ¾Ò»¶¨¾àÀëºó¾Í»áÎÞ·¨½ÓÊÕµ½Ðźţ¬ËùÒÔÒ»µ©À뿪»ùÕ¾¸½½ü£¬ÇмÇÒª½â³ýËø¶¨£»½â³ýËø¶¨µÄ·½·¨ÎªµÚ6²½ÖÐÔÚExcuteÊäÈë»ùÕ¾´úÂëʱÊäÈë125~ 511 ¡¢886ÒÔÉÏÉϵÄÆäËûÖµ(¿É²Î¼ûÉÏͼ)£¬ÉÔµÈÒ»»á¶ù£¬ÊÖ»úÐźÅÇøÓò»áÔÝʱûÐźţ¬µÈÖØÐÂÓÐÐźÅʱ£¬ÏÔʾ£º¡°BTS TEST OFF¡±£¬´Ëʱ½â³ýËø¶¨³É¹¦£»Èç¹ûûÓÐÏÔʾ¡°BTS TEST OFF¡±¿ÉÒÔ»»¸öÖµÔÙÊÔÑé¡£
ÓÑÇé·îËÍ: µ±ÊäÈë0~125 ¡¢512~885ÖÐÈÎÒâÒ»¸ö²»ÔÚCommon FID 01.03~ Common FID 01.05ÖÐÁгöµÄ»ùÕ¾ºÅ£¬Ôò¿ÉÒÔ´ïµ½¡±Äú²¦´òµÄµç»°ÔÝʱÎÞ·¨½Óͨ¡±µÄЧ¹û¡£
Èç¹û²»·ÅÐÄ£¬µ±À뿪»ùÕ¾ÇøÓòºó£¬¿ÉÒԻص½01.01£¬¿´¿´»ùÕ¾´úÂëÊDz»ÊÇÒÔÇ°Ëø¶¨µÄ´úÂ룬Èç¹û²»ÊǾͽâ³ýËø¶¨³É¹¦¡£
¸½Ôù×î¼ò±ã½â³ýËø¶¨µÄ·½·¨£ºÖ±½Ó¹Ø»úÔÙ¿ª»ú¾Í¿ÉÒÔ½â³ýËø¶¨¡£
¼´ÖØÆôºóËø¶¨»áʧЧ£¬ËùÒÔÖØÆôºóÈç¹û»¹Ïë¼ÌÐøËø¶¨£¬¾ÍÐèÒªÖØвÙ×÷¡£
8.ÆäËû˵Ã÷£º
a.ÓÉÓÚ²¢²»ÊÇËùÓеĻùÕ¾¶¼Éý¼¶ÎªEdge»ùÕ¾£¬ËùÒÔ¿ÉÒÔËø¶¨Edge»ùÕ¾´Ó¶ø»ñµÃ¸ü¸ßÁªÍøËٶȡ£
b.ÌøתÏÔʾµÄʱºò£¬Ò»Ñù¿ÉÒÔÑ¡ÔñÑ¡ÏîÖеġ±Change display¡±À´Ìøת£¬ÀýÈçÌøתµ½Common FID 01.12¿ÉÒÔÑ¡Ôñ¡±Change display¡±£¬È»ºóÊäÈë0112¾Í¿ÉÒÔÁË£¬Ê¾ÒâͼÈçÏ£º
ÓÉÓÚÈí¼þÊǹúÍ⹤³Ìʦ¿ª·¢,ËûÃǵÄ˵Ã÷²ÅÊÇ×îºÃµÄ,²ÎÊýµÄ½âÊÍÒ²ÊÇ×î׼ȷµÄ.
ÕâÀïÓÐÒ»¸öÓ¢ÎÄ°æµÄÏêϸ˵Ã÷Ê飬·Ç³£Ïêϸ£¬ÏëÒªÑо¿µÄ¿ÉÒÔÏÂÔØ:
FieldTestÓ¢ÎÄ˵Ã÷Êé(µã»÷ÏÂÔØ,ÎÞÐëÍþÍû)
1 INTRODUCTION 6
2 USING THE FIELD TEST DISPLAYS 6
General 6
Configuring FTD Displays 6
Activating the Field Test Displays 6
Deactivating the Field Test Displays 7
Field Test Display modes 7
2.1.1 Modes belonging in the use of the displays 7
2.1.2 Modes belonging in the field test display data 7
Signal and battery level 8
3 Information on the displays 8
Group 01: GSM Signaling displays, which can be visible to network operators 9
3.1.1 Display 01.01: Information of the serving cell 9
3.1.2 Display 01.02: More information of the serving cell 11
3.1.3 Display 01.03: Information of the serving cell, 1st and 2nd neighbor 12
3.1.4 Display 01.04: Information of the 3rd, 4th and 5th neighbor 13
3.1.5 Display 01.05: Information of the 6th, 7th and 8th neighbor 14
3.1.6 Display 01.06: Network selection display 16
3.1.7 Display 01.07: System information bits for serving cell. 16
3.1.8 Display 01.08: Values of paging repeat period, TMSI, periodic location update timer, AFC and AGC 18
3.1.9 Display 01.09: Network parameters 19
3.1.10 Display 01.10: Ciphering, hopping DTX status and IMSI 19
3.1.11 Display 01.11: Uplink DTX switching display 20
3.1.12 Display 01.12: Storing and removing BTS_TEST carrier 21
3.1.13 Display 01.13: Toggle Cell Barred Status 22
3.1.14 Display 01.14: Modify "last used band" 23
Group 02: GSM Registration and Mobility Displays 24
3.1.15 Display 02.01: Reset Registration and Mobility counters 24
3.1.16 Display 02.02: Neighbor Measurement Counter Display 24
3.1.17 Display 02.03: Search and reselection counter display 25
3.1.18 Display 02.04: Location update attempts counters 26
3.1.19 Display 02.05: Handover display, INTER CELL 26
3.1.20 Display 02.06: Handover display, INTRA CELL 27
3.1.21 Display 02.07: L2 display 28
Group 03: GSM memory handling 29
3.1.22 Display 03.01: SIM information 1 29
3.1.23 Display 03.02: SIM information 2 30
Group 04: GSM Test Timers, SMS and Call Counter Displays 31
3.1.24 Display 04.01: Reset test timers to zero and restart them 31
3.1.25 Display 04.02: Enable or disable test timers 31
3.1.26 Display 04.03: Test timer display 32
3.1.27 Display 04.04: Reset SMS and Call Counters to zero 33
3.1.28 Display 04.05: Call attempts counters 33
3.1.29 Display 04.06: Information about reasons for call clearing 34
3.1.30 Display 04.07: SMS attempts counters 35
3.1.31 Display 04.08: SMS timeout counters 35
3.1.32 Display 04.09: Toggle transmitter functionality 36
Group 05: GSM Data Displays 37
3.1.33 Display 05.01: HSCSD, Timeslot information display 37
3.1.34 Display 05.02: HSCSD, Timeslot power control level display 37
3.1.35 Display 05.03: Transparent data information 38
3.1.36 Display 05.04: Non transparent data 39
3.1.37 Display 05.05: Facsimile information 40
3.1.38 Display 05.06: CSD Server, main data display 41
3.1.39 Display 05.07: CSD Server, active DTE info ½, call related info 43
3.1.40 Display 05.08: CSD Server, active DTE info 2/2, GPDS, socket, conference info 44
Group 06: GPRS Signaling displays 46
3.1.41 Display 06.01: Information of the current GPRS state and previous TBF configuration 46
3.1.42 Display 06.02: Previous UL TBF establishment 47
3.1.43 Display 06.03: Information of the GMM state 48
3.1.44 Display 06.04: Values of P-TMSI, RAC, SMS radio priority, Ciphering and Non-DRX parameters 49
3.1.45 Display 06.05: GPRS Network parameters 50
3.1.46 Display 06.06: Packet common control channel parameters 51
3.1.47 Display 06.07: (Packet) System information parameters 52
3.1.48 Display 06.08: Cell re-selection parameters (serving cell) 52
3.1.49 Display 06.09: GPRS information of the serving cell, 1st, 2nd, and 3rd neighbor 53
3.1.50 Display 06.10: GPRS information of the 4th,5th and 6th neighbor 55
3.1.51 Display 06.11: GPRS information of the serving cell and 6 neighbors 56
Group 07: GPRS Data protocol displays 57
3.1.52 Display 07.01: Information of the first active PDP context 57
3.1.53 Display 07.02: Information of the second active PDP context 58
3.1.54 Display 07.03: Information of the RLC state 59
3.1.55 Display 07.04: RLC parameters 60
3.1.56 Display 07.05: RLC data block counters 60
3.1.57 Display 07.06: LLC data block counters 61
3.1.58 Display 07.07: LLC Ciphering parameters 61
3.1.59 Display 07.08: LLC parameters of the first SAPI 62
3.1.60 Display 07.09: LLC parameters of the second SAPI 63
3.1.61 Display 07.10: SNDC Data counters 63
3.1.62 Display 07.11: PPP information 64
Group10: Calypso specifig displays 64
3.1.63 Display 10.01 : Proximity Counter Display 64
3.1.64 Display 10.02 : Ambient Light sensor display 65
3.1.65 Display 10.03 : Vibra information 66
Group 61: Common EM (Energy Management) displays 66
3.1.66 Display 61.01: Basic EM information 66
3.1.67 Display 61.02: Basic BATMON4 information 68
3.1.68 Display 61.03: Advanced BATMON4 algorithm information 69
3.1.69 Display 61.04: Battery Monitor setup and log information 69
3.1.70 Display 61.05: PSM (Phone State Monitor) information 1 70
3.1.71 Display 61.06: PSM (Phone State Monitor) information 2 71
3.1.72 PSM (Phone State Monitor) information 3 71
3.1.73 Display 61.08: Basic charging information 72
3.1.74 Display 61.09: Extended charging information 74
3.1.75 Display 61.10: Extended charging information 2 75
3.1.76 Display 61.11: Configuration parameters etc. 76
Group 62: Common general displays 77
3.1.77 Display 62.01: Reasons for SW resets 77
3.1.78 Display 62.02: Counters 1-11 for resets 78
3.1.79 Display 62.03: Counters 12-19 for resets 79
3.1.80 Display 62.04: Information of the current MCU and DSP software versions 80
3.1.81 Display 62.05: Information of the current HW version 80
3.1.82 Display 62.06: Lights status control 81
3.1.83 Display 62.07: Disabling R&D Test Displays 81
3.1.84 Display 62.08: Reliability Test Display 82
Group 63: Common OS status displays 82
3.1.85 Display 63.01: OS Block usage statistics (Blocks 1-8) 83
3.1.86 Display 63.02: OS Block usage statistics (Blocks 9-16) 84
3.1.87 Display 63.03: OS block allocation errors 85
3.1.88 Display 63.04: Memory status before reset 86
3.1.89 Display 63.05: OS pre-reset error status 86
3.1.90 Display 63.06: OS current error status 87
3.1.91 Display 63.07: OS pre-reset warning status 88
3.1.92 Display 63.08: OS current warning status 88
3.1.93 Display 63.09: OS pre-reset remark status 89
3.1.94 Display 63.10: Display 63.10: OS current remark status 90
3.1.95 Display 63.11: Heap system status 90
3.1.96 Display 63.12: Heap top users 91
3.1.97 Display 63.13: Failed assertions 91
3.1.98 Display 63.14: OS pre-reset warning status 92
3.1.99 Display 63.14-63.29: Reserved for future use 92
3.1.100 Display 63.30: Information of OS_SYSTEM_STACK 93
3.1.101 Display 63.31-70 TASK_ID: Information of tasks 93
Group 65: Common PPC (Product Performance Counters) displays 95
3.1.102 Display 65.01: PPC Counters 1 95
3.1.103 Display 65.02: PPC Counters 2 95
3.1.104 Display 65.03: PPC Counters 3 96
Group 72: Bluetooth displays 97
3.1.105 Display 1: BT MCM Version info 97
3.1.106 Display 2: PPC Counter info 98
3.1.107 Display 3: Overall connection info 98
3.1.108 Display 4-5: Connection specific info 99
3.1.109 Display 6: Testing and status info 100
4 REFERENCES 101
3.Èç¹ûÊÇ°²×°°æ°²×°ºó¾Í¿ÉÒÔÖ±½ÓʹÓ㬲»ÐèÒªÖØÆôÊÖ»ú¡£
4.´ò¿ª³ÌÐòºó¿ÉÒÔ¿´µ½ÈçϽçÃ棬ͼƬÖеġ±Chanel num¡±´ú±íµ±Ç°ËùʹÓõĻùÕ¾´úÂ룬ºìȦËùʾµÄµØ·½Ö¸Ê¾µ±Ç°½çÃ棬Èç¹ûÄãҪѰÕÒ»ùÕ¾²¢Ëø¶¨µÄ»°£¬¿ÉÒÔ¼ÌÐø¿´ÏÂÈ¥£¬Èç¹ûÏëÏà¶ÔÏêϸµÄÁ˽⣬¿ÉÒԲο¼ÉÏÃæÌṩµØÖ·ÖеÄÎĵµ¡¶¹¤³ÌģʽÈí¼þʹÓÃС½â¡·¡£
5.°´Ï·½Ïò¼ü¿ÉÒÔÕýÏòÇл»½çÃæ(ÉÏ·½Ïò¼üÄæÏòÇл»½çÃæ)£¬Çл»µ½µ±Çл»½çÃæΪCommon FID 01.03¡¢Common FID 01.04¡¢Common FID 01.05µÄʱºò£¬¾Í¿ÉÒÔ¿´µ½¿ÉÓõĻùÕ¾´úÂë(ÈçÏÂͼºìȦλÖÃ)¡£
6.ÏòÏÂÇл»µ½Common FID 01.12½çÃ棬ÕâÊÇÑ¡ÏîÖлá¶à³öÒ»¸öÑ¡ÏExecute¡±,ÊäÈëÉÏÃæ¿´µ½µÄ»ùÕ¾´úÂëijһ¸ö¼´¿ÉËø¶¨»ùÕ¾£¬Ëø¶¨ºó²âÊÔÐźźÍÏÂÔØËٶȣ¬×îºóËø¶¨Ð§¹û×îºÃµÄ¡£
7.Ëø¶¨»ùÕ¾ºó£¬Èç¹ûÄãÀë»ùÕ¾Ò»¶¨¾àÀëºó¾Í»áÎÞ·¨½ÓÊÕµ½Ðźţ¬ËùÒÔÒ»µ©À뿪»ùÕ¾¸½½ü£¬ÇмÇÒª½â³ýËø¶¨£»½â³ýËø¶¨µÄ·½·¨ÎªµÚ6²½ÖÐÔÚExcuteÊäÈë»ùÕ¾´úÂëʱÊäÈë125~ 511 ¡¢886ÒÔÉÏÉϵÄÆäËûÖµ(¿É²Î¼ûÉÏͼ)£¬ÉÔµÈÒ»»á¶ù£¬ÊÖ»úÐźÅÇøÓò»áÔÝʱûÐźţ¬µÈÖØÐÂÓÐÐźÅʱ£¬ÏÔʾ£º¡°BTS TEST OFF¡±£¬´Ëʱ½â³ýËø¶¨³É¹¦£»Èç¹ûûÓÐÏÔʾ¡°BTS TEST OFF¡±¿ÉÒÔ»»¸öÖµÔÙÊÔÑé¡£
ÓÑÇé·îËÍ: µ±ÊäÈë0~125 ¡¢512~885ÖÐÈÎÒâÒ»¸ö²»ÔÚCommon FID 01.03~ Common FID 01.05ÖÐÁгöµÄ»ùÕ¾ºÅ£¬Ôò¿ÉÒÔ´ïµ½¡±Äú²¦´òµÄµç»°ÔÝʱÎÞ·¨½Óͨ¡±µÄЧ¹û¡£
Èç¹û²»·ÅÐÄ£¬µ±À뿪»ùÕ¾ÇøÓòºó£¬¿ÉÒԻص½01.01£¬¿´¿´»ùÕ¾´úÂëÊDz»ÊÇÒÔÇ°Ëø¶¨µÄ´úÂ룬Èç¹û²»ÊǾͽâ³ýËø¶¨³É¹¦¡£
¸½Ôù×î¼ò±ã½â³ýËø¶¨µÄ·½·¨£ºÖ±½Ó¹Ø»úÔÙ¿ª»ú¾Í¿ÉÒÔ½â³ýËø¶¨¡£
¼´ÖØÆôºóËø¶¨»áʧЧ£¬ËùÒÔÖØÆôºóÈç¹û»¹Ïë¼ÌÐøËø¶¨£¬¾ÍÐèÒªÖØвÙ×÷¡£
8.ÆäËû˵Ã÷£º
a.ÓÉÓÚ²¢²»ÊÇËùÓеĻùÕ¾¶¼Éý¼¶ÎªEdge»ùÕ¾£¬ËùÒÔ¿ÉÒÔËø¶¨Edge»ùÕ¾´Ó¶ø»ñµÃ¸ü¸ßÁªÍøËٶȡ£
b.ÌøתÏÔʾµÄʱºò£¬Ò»Ñù¿ÉÒÔÑ¡ÔñÑ¡ÏîÖеġ±Change display¡±À´Ìøת£¬ÀýÈçÌøתµ½Common FID 01.12¿ÉÒÔÑ¡Ôñ¡±Change display¡±£¬È»ºóÊäÈë0112¾Í¿ÉÒÔÁË£¬Ê¾ÒâͼÈçÏ£º
ÓÉÓÚÈí¼þÊǹúÍ⹤³Ìʦ¿ª·¢,ËûÃǵÄ˵Ã÷²ÅÊÇ×îºÃµÄ,²ÎÊýµÄ½âÊÍÒ²ÊÇ×î׼ȷµÄ.
ÕâÀïÓÐÒ»¸öÓ¢ÎÄ°æµÄÏêϸ˵Ã÷Ê飬·Ç³£Ïêϸ£¬ÏëÒªÑо¿µÄ¿ÉÒÔÏÂÔØ:
FieldTestÓ¢ÎÄ˵Ã÷Êé(µã»÷ÏÂÔØ,ÎÞÐëÍþÍû)
1 INTRODUCTION 6
2 USING THE FIELD TEST DISPLAYS 6
General 6
Configuring FTD Displays 6
Activating the Field Test Displays 6
Deactivating the Field Test Displays 7
Field Test Display modes 7
2.1.1 Modes belonging in the use of the displays 7
2.1.2 Modes belonging in the field test display data 7
Signal and battery level 8
3 Information on the displays 8
Group 01: GSM Signaling displays, which can be visible to network operators 9
3.1.1 Display 01.01: Information of the serving cell 9
3.1.2 Display 01.02: More information of the serving cell 11
3.1.3 Display 01.03: Information of the serving cell, 1st and 2nd neighbor 12
3.1.4 Display 01.04: Information of the 3rd, 4th and 5th neighbor 13
3.1.5 Display 01.05: Information of the 6th, 7th and 8th neighbor 14
3.1.6 Display 01.06: Network selection display 16
3.1.7 Display 01.07: System information bits for serving cell. 16
3.1.8 Display 01.08: Values of paging repeat period, TMSI, periodic location update timer, AFC and AGC 18
3.1.9 Display 01.09: Network parameters 19
3.1.10 Display 01.10: Ciphering, hopping DTX status and IMSI 19
3.1.11 Display 01.11: Uplink DTX switching display 20
3.1.12 Display 01.12: Storing and removing BTS_TEST carrier 21
3.1.13 Display 01.13: Toggle Cell Barred Status 22
3.1.14 Display 01.14: Modify "last used band" 23
Group 02: GSM Registration and Mobility Displays 24
3.1.15 Display 02.01: Reset Registration and Mobility counters 24
3.1.16 Display 02.02: Neighbor Measurement Counter Display 24
3.1.17 Display 02.03: Search and reselection counter display 25
3.1.18 Display 02.04: Location update attempts counters 26
3.1.19 Display 02.05: Handover display, INTER CELL 26
3.1.20 Display 02.06: Handover display, INTRA CELL 27
3.1.21 Display 02.07: L2 display 28
Group 03: GSM memory handling 29
3.1.22 Display 03.01: SIM information 1 29
3.1.23 Display 03.02: SIM information 2 30
Group 04: GSM Test Timers, SMS and Call Counter Displays 31
3.1.24 Display 04.01: Reset test timers to zero and restart them 31
3.1.25 Display 04.02: Enable or disable test timers 31
3.1.26 Display 04.03: Test timer display 32
3.1.27 Display 04.04: Reset SMS and Call Counters to zero 33
3.1.28 Display 04.05: Call attempts counters 33
3.1.29 Display 04.06: Information about reasons for call clearing 34
3.1.30 Display 04.07: SMS attempts counters 35
3.1.31 Display 04.08: SMS timeout counters 35
3.1.32 Display 04.09: Toggle transmitter functionality 36
Group 05: GSM Data Displays 37
3.1.33 Display 05.01: HSCSD, Timeslot information display 37
3.1.34 Display 05.02: HSCSD, Timeslot power control level display 37
3.1.35 Display 05.03: Transparent data information 38
3.1.36 Display 05.04: Non transparent data 39
3.1.37 Display 05.05: Facsimile information 40
3.1.38 Display 05.06: CSD Server, main data display 41
3.1.39 Display 05.07: CSD Server, active DTE info ½, call related info 43
3.1.40 Display 05.08: CSD Server, active DTE info 2/2, GPDS, socket, conference info 44
Group 06: GPRS Signaling displays 46
3.1.41 Display 06.01: Information of the current GPRS state and previous TBF configuration 46
3.1.42 Display 06.02: Previous UL TBF establishment 47
3.1.43 Display 06.03: Information of the GMM state 48
3.1.44 Display 06.04: Values of P-TMSI, RAC, SMS radio priority, Ciphering and Non-DRX parameters 49
3.1.45 Display 06.05: GPRS Network parameters 50
3.1.46 Display 06.06: Packet common control channel parameters 51
3.1.47 Display 06.07: (Packet) System information parameters 52
3.1.48 Display 06.08: Cell re-selection parameters (serving cell) 52
3.1.49 Display 06.09: GPRS information of the serving cell, 1st, 2nd, and 3rd neighbor 53
3.1.50 Display 06.10: GPRS information of the 4th,5th and 6th neighbor 55
3.1.51 Display 06.11: GPRS information of the serving cell and 6 neighbors 56
Group 07: GPRS Data protocol displays 57
3.1.52 Display 07.01: Information of the first active PDP context 57
3.1.53 Display 07.02: Information of the second active PDP context 58
3.1.54 Display 07.03: Information of the RLC state 59
3.1.55 Display 07.04: RLC parameters 60
3.1.56 Display 07.05: RLC data block counters 60
3.1.57 Display 07.06: LLC data block counters 61
3.1.58 Display 07.07: LLC Ciphering parameters 61
3.1.59 Display 07.08: LLC parameters of the first SAPI 62
3.1.60 Display 07.09: LLC parameters of the second SAPI 63
3.1.61 Display 07.10: SNDC Data counters 63
3.1.62 Display 07.11: PPP information 64
Group10: Calypso specifig displays 64
3.1.63 Display 10.01 : Proximity Counter Display 64
3.1.64 Display 10.02 : Ambient Light sensor display 65
3.1.65 Display 10.03 : Vibra information 66
Group 61: Common EM (Energy Management) displays 66
3.1.66 Display 61.01: Basic EM information 66
3.1.67 Display 61.02: Basic BATMON4 information 68
3.1.68 Display 61.03: Advanced BATMON4 algorithm information 69
3.1.69 Display 61.04: Battery Monitor setup and log information 69
3.1.70 Display 61.05: PSM (Phone State Monitor) information 1 70
3.1.71 Display 61.06: PSM (Phone State Monitor) information 2 71
3.1.72 PSM (Phone State Monitor) information 3 71
3.1.73 Display 61.08: Basic charging information 72
3.1.74 Display 61.09: Extended charging information 74
3.1.75 Display 61.10: Extended charging information 2 75
3.1.76 Display 61.11: Configuration parameters etc. 76
Group 62: Common general displays 77
3.1.77 Display 62.01: Reasons for SW resets 77
3.1.78 Display 62.02: Counters 1-11 for resets 78
3.1.79 Display 62.03: Counters 12-19 for resets 79
3.1.80 Display 62.04: Information of the current MCU and DSP software versions 80
3.1.81 Display 62.05: Information of the current HW version 80
3.1.82 Display 62.06: Lights status control 81
3.1.83 Display 62.07: Disabling R&D Test Displays 81
3.1.84 Display 62.08: Reliability Test Display 82
Group 63: Common OS status displays 82
3.1.85 Display 63.01: OS Block usage statistics (Blocks 1-8) 83
3.1.86 Display 63.02: OS Block usage statistics (Blocks 9-16) 84
3.1.87 Display 63.03: OS block allocation errors 85
3.1.88 Display 63.04: Memory status before reset 86
3.1.89 Display 63.05: OS pre-reset error status 86
3.1.90 Display 63.06: OS current error status 87
3.1.91 Display 63.07: OS pre-reset warning status 88
3.1.92 Display 63.08: OS current warning status 88
3.1.93 Display 63.09: OS pre-reset remark status 89
3.1.94 Display 63.10: Display 63.10: OS current remark status 90
3.1.95 Display 63.11: Heap system status 90
3.1.96 Display 63.12: Heap top users 91
3.1.97 Display 63.13: Failed assertions 91
3.1.98 Display 63.14: OS pre-reset warning status 92
3.1.99 Display 63.14-63.29: Reserved for future use 92
3.1.100 Display 63.30: Information of OS_SYSTEM_STACK 93
3.1.101 Display 63.31-70 TASK_ID: Information of tasks 93
Group 65: Common PPC (Product Performance Counters) displays 95
3.1.102 Display 65.01: PPC Counters 1 95
3.1.103 Display 65.02: PPC Counters 2 95
3.1.104 Display 65.03: PPC Counters 3 96
Group 72: Bluetooth displays 97
3.1.105 Display 1: BT MCM Version info 97
3.1.106 Display 2: PPC Counter info 98
3.1.107 Display 3: Overall connection info 98
3.1.108 Display 4-5: Connection specific info 99
3.1.109 Display 6: Testing and status info 100
4 REFERENCES 101
»Ø´ðÕߣº
wangyuan072
»Ø´ðʱ¼ä£º2009-06-04 23:28
3 14
ÈȵãÎÊÌâ
¸ü¶à¾«²Ê
ÁªÏµÎÒÃÇ - ÎÊͨÐÅר¼Ò | Powered by MSCBSC Òƶ¯Í¨ÐÅÍø © 2006 - |