问题已开启 (普通问题)
跨BSC切换之后导致单通
被叫上发connect之后,主叫切换到另外一个BSC的小区,随之主叫接通 ,接通之后出现类似单通的现象,主叫始终只能听见被叫的振铃声(测试手机未开启彩铃),被叫则在接通之后听不见任何声音。检查两个BSC的A口占用没有发现异常,检查两个基站的话务报告和上、下行干扰情况没有发现异常。
可能这个问题比较棘手,工作好几年了确实还没有碰到此类情况,恳请各位大侠帮忙查处一下,谢谢啦!下面是主被叫的信令,均是正常的:
主叫信令:
17:48:19.09MS1 RR Measurement Report
17:48:19.53MS1 RR System Information Type 5ter
17:48:19.57MS1 RR Measurement Report
17:48:19.60MS1 CC Alerting
17:48:19.60MS1 Call Setup
17:48:19.71MS1 RR Synch Channel Information
17:48:20.01MS1 RR System Information Type 6
17:48:20.07MS1 RR Measurement Report
17:48:20.50MS1 RR System Information Type 5
17:48:20.54MS1 RR Measurement Report
17:48:20.96MS1 RR System Information Type 5ter
17:48:21.01MS1 RR Measurement Report
17:48:21.39MS1 RR Synch Channel Information
17:48:21.45MS1 RR System Information Type 6
17:48:21.50MS1 RR Measurement Report
17:48:21.51MS1 RR Synch Channel Information
17:48:21.93MS1 RR System Information Type 5
17:48:21.98MS1 RR Measurement Report
17:48:22.40MS1 RR System Information Type 5ter
17:48:22.48MS1 RR Measurement Report
17:48:23.07MS1 RR System Information Type 6
17:48:23.07MS1 RR Handover Command
17:48:23.09MS1 RR Measurement Report
17:48:23.09MS1 RR Handover Access
17:48:23.10MS1 RR Handover Complete
17:48:23.10MS1 Handover
17:48:23.43MS1 CC Connect
17:48:23.43MS1 Call Established
17:48:23.45MS1 CC Connect Acknowledge
17:48:23.65MS1 RR System Information Type 5
17:48:23.70MS1 RR Measurement Report
被叫信令:
17:48:19.04MS2 RR Assignment Command
17:48:19.09MS2 RR Assignment Complete
17:48:19.20MS2 CC Alerting
17:48:19.20MS2 Call Setup
17:48:19.71MS2 RR System Information Type 5
17:48:19.76MS2 RR Measurement Report
17:48:20.20MS2 RR System Information Type 5ter
17:48:20.23MS2 RR Measurement Report
17:48:20.67MS2 RR System Information Type 6
17:48:20.71MS2 RR Measurement Report
17:48:21.15MS2 RR System Information Type 5
17:48:21.20MS2 RR Measurement Report
17:48:21.64MS2 RR System Information Type 5ter
17:48:21.68MS2 RR Measurement Report
17:48:21.81MS2 RR Synch Channel Information
17:48:21.93MS2 RR Synch Channel Information
17:48:22.10MS2 RR System Information Type 6
17:48:22.15MS2 RR Measurement Report
17:48:22.59MS2 RR System Information Type 5
17:48:22.64MS2 RR Measurement Report
17:48:23.07MS2 RR Synch Channel Information
17:48:23.07MS2 CC Connect
17:48:23.09MS2 RR Synch Channel Information
17:48:23.10MS2 CC Connect Acknowledge
17:48:23.10MS2 Call Established
17:48:23.12MS2 RR System Information Type 5ter
17:48:23.12MS2 RR Measurement Report
提问者: rainy  提问时间: 2010-06-12    
 
  我要回答:
 

  请先 登录注册 再回答问题

更多 BSC 单通 切换 相关问题
问题答案 ( 0 )
中国通信人才网 | 江苏通信人才网 | 山东通信人才网 | 武汉通信人才网 | 浙江通信人才网 | 湖南通信人才网
重庆信科通信工程有限公司 聘:移动通信无线网络优化工程师
需求人数:10 人 地点:贵州省,四川省,西安市,云南省,江西省
嘉环科技股份有限公司 聘:测试工程师
需求人数:15 人 地点:昆明市,临沧市,德宏州,红河州,玉溪市
杭州东信网络技术有限公司 聘:沧州-高/中/初级-网优工程师
需求人数:30 人 地点:沧州市
西安长河通讯有限责任公司 聘:核心网工程师
需求人数:5 人 地点:东南亚
南京华苏科技有限公司 聘: 4&5G高级优化工程师
需求人数:5 人 地点:福州市
浙江明讯网络技术有限公司 聘:西安远程交付GSC项目工程师
需求人数:30 人 地点:西安市
润建股份有限公司 聘:网优规划工程师
需求人数:3 人 地点:杭州市
怡利科技发展有限公司 聘:5G中级后台优化工程师
需求人数:5 人 地点:乌鲁木齐市,伊宁市
陕西瑞达沣通信技术有限公司 聘:华为光网络工程师-新疆
需求人数:2 人 地点:乌鲁木齐市
南京格安信息系统有限责任公司 聘:福建4/5G中高级后台工程师
需求人数:3 人 地点:福州市,宁德市
热点问题
更多精彩

联系我们 - 问通信专家 Powered by MSCBSC 移动通信网  © 2006 -